Skip to content. Home About. Introduction Protection relay settings in power system plays a very vital role for safe operation of power system ensuring minimal outage to end user thereby contributing to less loss in terms of financial matters to utility as well.

Depending upon the time of operations relays may be classified as: Standard Inverse Definite Time Relay These are relay whose operating time is approximately inversely proportional to fault current near pick up value and becomes substantially constant slightly above the pick-up value of the relay. Extremely Inverse Relay This relays are used for the protection of transformer, cables and feeders because it is possible to achieve accurate discrimination with fuses and auto re-closures in their case.

Very Inverse Relay The time current characteristic is inverse over a greater range and after saturation tends to definite time. Relay Co-ordination The basic of parameter calculation is same as explained above but the objective of coordination shall be such that fault at any place must be cleared by substation near it and should not migrate upstream or downstream.

A single line diagram of the power system. The impedance of the transformers, feeders, in ohm or in PU. Type and rating of the protective devices and transformer. Writing Setting Parameters to Relay In this blog, setting the calculated parameters to relay has been shown. Step 5: After addition of relays, go to application configuration, then to protection, then to settings and then to your desired protection as shown below: Step 6: Since I am only dealing with overcurrent protection in this blog, thus for that we need to go for current protection and then to PHLPTOC1 which is ANSI code for low set over current first instance 1 overcurrent protection.

Share this: Twitter Facebook. Like this: Like Loading Our website uses cookies which are necessary for running the website and for providing the services you request. We would also like to set the following optional cookies on your device. You can change these settings any time later by clicking "Change cookie settings" at the bottom of any page. For more information, please read our Cookie Information. We collect statistics in order to understand how our visitors interact with the website and how we can improve it.

The cookies collect information in a way that does not directly identify anyone. We store choices you have made so that they are remembered when you visit our website again in order to provide you a more personalized experience. Protection relays. Did you know… To browse Academia. Log in with Facebook Log in with Google. Remember me on this computer. Enter the email address you signed up with and we'll email you a reset link.

Need an account? Click here to sign up. Download Free PDF. Numerical relay protection coordination using simulation software.

Srete Nikolovski. Predrag Maric. Mario Havranek. A short summary of this paper. Download Download PDF. Translate PDF. Havranek , P. Multifunctional numerical relays with current transformers which it uses.

Overcurrent, overvoltage, undervoltage, directional overcurrent, underfrequency and overfrequenecy functions have been used for protection coordination. Different relay characteristics have been presented in one time-overcurrent plot.

The damage curve and characteristic currents of electrical equipment in the network have been shown to set the relay tripping times and current settings and for a good and thorough protection of the equipment. Protection coordination settings have been checked and verified simulating faults with the real system values. For better understanding such a task, power system simulation tools are used. Small power plant renewable source connection to numerical relays that contains time-curent curves of all distribution network protective devices.

The time-current curves TCC can be coordinated with each other and with the short circuit analysis results. Introduction The selected protection principle affects the operating speed of the protection , which has a significant im- pact on the harm caused by short circuits.

Selective short-circuit protection can be achieved in different ways, such as: Time-graded protection Time- and current-graded protection Time- and direction-graded protection Current- and impedance-graded protection Interlocking protection Differential protection. Share this: Twitter Facebook. Like this: Like Loading Leave a Reply Cancel reply Enter your comment here Fill in your details below or click an icon to log in:.